TH801 Thermo-HygrometerTH90 Moisture Meter

TH90 Thermo-Hygrometer Thermo-Hygrometer

1,400.00 ฿

Availability: Please ask.

TH90 Thermo-Hygrometer Thermo-Hygrometer (TH801) With ISO / IEC 17025 CERTIFICATE OF CALIBRATION !!!!
Ask a question about this product
Product Tags

Thermometer TH90 Thermometer (TH801)

Confident in performance. With ISO / IEC 17025 CERTIFICATE OF CALIBRATION !!!!

Features of Thermometer Thermometer TH801

  • Large digital LCD display
  • Display temperature - 10 C ~ 50 C Resolution 0.1 C Accuracy +/- 1 C
  • Moisture 20% to 99% Resolution 1% Rh Accuracy +/- 5% (Range 40-80% RH)
  • The record shows the minimum value.
  • Can display both C and F
  • Battery Powered 1.5 V

General Information

  • Show temperature, humidity and time.
  • Can save the maximum value of the measurement.
  • Select the time display mode for 12 hours or 24 hours.
  • Choose a temperature in degrees Celsius or Fahrenheit.
  • Alarm Timer
  • Show dates and months.
  • Can be installed either a desktop or a hanging.

Technical specifications: Specification

  • Temperature range -10 to + 50 C (-14 to 122 F)
  • Measuring range 20% to 99% RH
    • 0.1C temperature measurement resolution (0.1F)
    • Resolution of moisture measurement 1% RH
  • Accuracy
    • Temperature +/- 1C (1.8F)
    • +/- 5% RH
  • 1.5 1 BATTERY XNUMX BATTERY
  • Machine Dimensions 100 x 108 x 20 mm
  • Weight approx.
  • Storage Conditions -20C to 60C, 20 to 80% RH

Using

Close the battery compartment cover. Follow the directions on the lid.

2

a. (MODE): Use to enter the date mode.

b. (ADJ): Used to adjust the date setting.

c. (MEMORY): Used to view the minimum value of the readable value.

d. (RESET) Rear: Used to clear the settings and record the maximum.

Press and hold the MODE button for about 3 seconds to enter the setting mode. After that, the screen number flashes to adjust the minutes by pressing the ADJ button and pressing the mode again after the desired value. The screen will flash in hours, hours, and days. The value can be adjusted according to the number.

4. In normal readings (symbol: between hours and minutes flashes). Press the MODE button to enter the alarm setting mode. (Symbol: between hours and minutes. Press the ADJ. Button to turn the alarm setting mode on or off, then press and hold the MODE button again for 2 seconds, and then set the alarm time as 3.

5. If the machine is in alarm setting mode and the machine is not set. By pressing the button at all. The unit will automatically return to the measurement mode within 1 minutes.

6. In the machine state is in the measurement mode, can press the ADJ button to see the date and month, then the machine will automatically return to the measurement mode within 3 seconds.

7 Press the MEMORY 1 button once to see the maximum value. Press 1 again to view the minimum value, and if you hold down 2, the machine will clear the record.

  • Sample of Certificate of Calibration: Sample of Calibration