FREE DELIVERY!

3,000 BONUS * Free Shipping KERRY

Technical Support

Test Shop After-sales service

OPEN (MON-SAT)

8.00-17.30 (Mon-Fri) 9.00-15.30 (Sat)

MI180MI180

MIXING MACHINE pH, ORP, conductivity, TDS and NaCl

32,700.00 ฿

Availability: Please ask.

MIXER MILWAUKEE pH, ORP, conductivity, TDS and NaCl Laboratory
Ask a question about this product
Product Tags

Measuring device pH / ORP / EC / TDS / NaCl / Temp Model Table MI180

pH / ORP / Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter

Mi180 The 6 parameter can be measured. pH/ ORP / EC /TDS (Including dissolved in solids), percent NaCl, andtemperatureMI180

To calibrate pH Calibration can also be selected in 3. Standard buffer 7 value for calibration is very accurate, even when sample testing has a very wide difference in pH measurement.

Features for measuring EC And TDS is automatic adjustment of the measurement area to suit the sample value being tested.

All measurements can be compensated. temperature Automatic at 20 or 25 ° C and can enter values. temperature The user.

Automatic temperature compensation can also be used for automatic temperature compensation for measurements. Conductivity True, the stability indicator on the LCD screen ensures accuracy.

Measuring tools Mi180 The 4 Probe that comes with the GLP feature gauge allows users to store and retrieve status information via a compatible PC system via RS232 or USB port.

SPECIFICATIONS
pH Range -2.00 is 16.00 pH; -2.000 to 16.000 pH
mV Range ± 699.9 mV; ± 2000 mV
EC Range 0.00 is 29.99 μS / cm; 30.0 is 299.9 μS / cm; 300 is 2999 μS / cm; 3.00 is 29.99 mS / cm; 30.0 is 200.0 mS / cm; up to 500.0 mS / cm uncompensed EC *
TDS Range 0.0 is 14.99 mg / l (ppm); 15.0 is 149.9 mg / l (ppm); 150 is 1499 mg / l (ppm); 1.50 is 14.99 g / l (ppt); 15.0 is 100.0 g / l (ppt); up to 400.0 g / l actual TDS * (với 0.80 factor)
NaCl Range 0.0 to 400.0%
Temp Range -20.0 is 120.0 ° C / -4.0 to 248.0 ° F
pH Resolution 0.01 pH; 0.001 pH
mV Resolution 0.1 mV; 1 mV
EC Resolution 0.01 μS / cm; 0.1 μS / cm; 1 μS / cm; 0.01 mS / cm; 0.1 mS / cm;
TDS Resolution 0.01 mg / l; 0.1 mg / l; 1.0 mg / l; 0.01 g / l; 0.1 g / l
NaCl Resolution 0.1%
Resolution Temp 0.1 ° C / 0.1 ° F
pH Accuracy ± 0.01 pH; ± 0.002 pH
mV Accuracy ± 0.2 mV; ± 1 mV
EC Accuracy ± 1% of reading ± (0.05 μS / cm or 1)
TDS Accuracy ± 1% of reading ± (0.03 ppm hoặc 1)
NaCl Accuracy ± 1% of reading
Temp Accuracy ± 0.4 ° C / ± 0.8 ° F
Rel mV Offset ± 2000 mV
PH Calibration 1, 2, 3, 7, 1.68, 4.01, 6.86, 7.01 and 9.18.
EC Calibration 1 point slope calibration with 6 memorized solutions: (84 μS / cm, 1413 μS / cm, 5.00 μS / cm, 12.88 μS / cm, 80.0 μS / cm, 111.8 mS / cm)
NaCl Calibration 1 điểm, với MA9066 solution
Temp Calibration 2 point, 0 and 50 ° C / 32 and 122 ° F
Temperature Compensation 20.0 ° C / -120.0 to 4.0 ° FF
Temperature Coefficient select by 0.00 to 6.00% / ° C (EC and TDS only)
pH Electrodes & Temp Probe MA814DB / 1 & MA917B / 1 & MA831R (included)
TDS Factor 0.40 là 0.80 (giá trị mặc định là 0.50)
Log on demand up to 50 samples on each range (pH, mV, EC, TDS, NaCl)
GLP last pH, EC, NaCl calibration data
PC Interface RS232 / USB Opto-isolated
Environment 0 is 50 ° C / 32 is 122 ° F; max RH 95%
Power supply 12 VDC power adapter (included)
Dimensions 230 x 160 x 95 mm
Weight <spa
MI180
Product Information
Datasheet Product Brochure
User manual Measuring tool
Milwaukee Catalog Measuring tool